USAfixTM - Repair Guide (RG) - Master Email RG
- Check for Power to the Motor
 Level of Difficulty - HIGH  Estimated Completion Time - 15 minutes
TASKI - SWINGO XP

Tools Required
Tool 
Screwdriver-flat tip
Torx T30
Volt meter (True RMS capable)

Parts Required


Step Procedure & Parts & Tools
1 TURN THE KEY TO THE OFF POSITION.

2 PULL THE TANK COVER HANDLE OUT AT FRONT OF COVER AND RAISE THE COVER UP TO OPEN.

3 REMOVE THE 6 SCREWS FROM THE VAC MOTOR PLATE.
Torx T30

4 REMOVE THE VAC MOTOR COVER FROM MACHINE.

5 SLIDE THE VAC MOTOR COLLAR OUT TO REMOVE THE VAC MOTOR FROM THE MACHINE.

6 TO ACTIVATE THE MACHINE, TURN THE KEY ON. YOU WILL NEED TO BYPASS THE STEPBOARD SWITCH AS THE MACHINE WILL NOT ACTIVATE WITHOUT SOMEONE STANDING ON THE STEP BOARD. TO BYPASS THE STEP BOARD SWITCH, LOCATE THE STEP BOARD SWITCH UNDER STEP BOARD. INSERT SCREWDRIVER ABOVE SWITCH AND BELOW THE STEP BOARD.
Screwdriver-flat tip

7 DISCONNECT THE WHITE CONNECTOR PLUG INSERT PROBES INTO THE CONNECTOR PLUG. RED PROBE TO RED WIRE AND BLACK PROBE TO BLACK WIRE. CHECK READING ON VOLT METER. VOLT METER SHOULD READ 24 VOLTS.
Volt meter (True RMS capable)